Item
|
Specifications
|
Condition
|
Breakdown voltage
|
Between input and output
|
2,000 Vrms
|
for 1 min.
|
Between different terminals (between relays, both ways)
|
1,500 Vrms
|
for 1 min.
|
Insulation resistance
|
Min. 100 MΩ (Measurement at same location as “Breakdown voltage” section.)
|
Using 500 V DC megger
|
Vibration resistance (destructive)
|
10 to 55 Hz at double amplitude
1 mm .039 inch
|
In vertical, horizontal and longitudinal directions
|
Vibration resistance (functional)
|
10 to 55 Hz at double amplitude
1 mm .039 inch
|
|
Shock resistance (destructive)
|
Min. 196 m/s2
|
In vertical, horizontal and longitudinal directions
|
Shock resistance (functional)
|
Min. 98 m/s2
|
In vertical, horizontal and longitudinal directions
|
Ambient temperature
|
-20°C to +55°C - 4°F to +131°F
|
Not freezing and condensing
|
Ambient humidity
|
35% to 85% R.H.
|
Not condensing
|
Storage temperature
|
-30°C to +80°C -22°F to +176°F
|
Not freezing and condensing
|
Terminal screw fasten torque
|
0.3 to 0.5 Nm
|
|
Coil surge absorber
|
Diode (1 A, 400 V)
|
|
Cross connection protecting diode
|
1 A, inverse voltage 400 V
|
|
Unit weight
|
Approx. 100 g 3.53 oz
|
|